striped line
Department of Civil Engineering
CIVL 3121 - Tensile Pull-Out Force
set cell vertical height
Below is an estimate of the tensile pull-out force of K'NEX rod from a K'NEX connector for various modes of connection.

 

Mode Pull-Out Force (lbs)
1 19.6
2 28.7
3 36.8

Final values

 

Test Pull-Out Force (grams)
Mode 1 Mode 2 Mode 3
1 9,200 12,100 15,600
2 8,600 12,700 14,700
3 8,800 14,000 15,200
4 8,500 13,400 18,300
5 9,400 12,800 19,700
Average (lbs.) 19.6 28.7 36.8

 